###### (Automatically generated documentation) # Create ASHRAE 90.1-2019 PRM Model ## Description Create the Baseline Building per ASHRAE Standard 90.1-2019 Performance Rating Method. User manual for this measure please see https://pnnl.github.io/BEM-for-PRM . ## Modeler Description ## Measure Type ModelMeasure ## Taxonomy ## Arguments ### Default Building Area Type for Window To Wall Ratio: Select default building type for WWR assignment based on 90.1 Appendix G table G3.1.1-1. **Name:** building_type_wwr, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["Grocery store", "Healthcare (outpatient)", "Hospital", "Hotel/motel <= 75 rooms", "Hotel/motel > 75 rooms", "Office <= 5,000 sq ft", "Office 5,000 to 50,000 sq ft", "Office > 50,000 sq ft", "Restaurant (quick service)", "Restaurant (full service)", "Retail (stand alone)", "Retail (strip mall)", "School (primary)", "School (secondary and university)", "Warehouse (nonrefrigerated)", "All others"] ### Default Building Area Type for Service Water Heating: Select default building type for SWH system type assignment based on 90.1 Appendix G table G3.1.1-2. **Name:** building_type_swh, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["Automotive facility", "Performing arts theater", "Convenience store", "Police station", "Convention center", "Post office", "Courthouse", "Religious facility", "Dining: Bar lounge/leisure", "Retail", "Dining: Cafeteria/fast food", "School/university", "Dining: Family", "Sports arena", "Dormitory", "Town hall", "Exercise center", "Transportation", "Fire station", "Warehouse", "Grocery store", "Workshop", "Gymnasium", "Health-care clinic", "Hospital and outpatient surgery center", "Hotel", "Library", "Manufacturing facility", "Motel", "Motion picture theater", "Multifamily", "Museum", "Office", "Parking garage", "Penitentiary", "All others"] ### Default Building Type for HVAC: Select default building type for HVAC system type assignment based on 90.1 Appendix G table G3.1.1-3. **Name:** building_type_hvac, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["retail", "other nonresidential", "public assembly", "residential", "unconditioned", "heated-only storage", "hospital"] ### Climate Zone: **Name:** climate_zone, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["ASHRAE 169-2013-1A", "ASHRAE 169-2013-1B", "ASHRAE 169-2013-2A", "ASHRAE 169-2013-2B", "ASHRAE 169-2013-3A", "ASHRAE 169-2013-3B", "ASHRAE 169-2013-3C", "ASHRAE 169-2013-4A", "ASHRAE 169-2013-4B", "ASHRAE 169-2013-4C", "ASHRAE 169-2013-5A", "ASHRAE 169-2013-5B", "ASHRAE 169-2013-5C", "ASHRAE 169-2013-6A", "ASHRAE 169-2013-6B", "ASHRAE 169-2013-7A", "ASHRAE 169-2013-7B", "ASHRAE 169-2013-8A", "ASHRAE 169-2013-8B", "ASHRAE 169-2006-1A", "ASHRAE 169-2006-1B", "ASHRAE 169-2006-2A", "ASHRAE 169-2006-2B", "ASHRAE 169-2006-3A", "ASHRAE 169-2006-3B", "ASHRAE 169-2006-3C", "ASHRAE 169-2006-4A", "ASHRAE 169-2006-4B", "ASHRAE 169-2006-4C", "ASHRAE 169-2006-5A", "ASHRAE 169-2006-5B", "ASHRAE 169-2006-5C", "ASHRAE 169-2006-6A", "ASHRAE 169-2006-6B", "ASHRAE 169-2006-7A", "ASHRAE 169-2006-7B", "ASHRAE 169-2006-8A", "ASHRAE 169-2006-8B"] ### Exempt From Rotations: Select TRUE if the building has rating authority approval that orientation is dictated by site considerations. Note: user data could override this selection. **Name:** exempt_from_rotations, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["TRUE", "FALSE"] ### Exempt From Unmet Load Hours Check: Select TRUE if rating authority has approved allowing the models to exceed the specified values in Appendix G. **Name:** exempt_from_unmet_load_hours_check, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["TRUE", "FALSE"] ### Use User Data Project user compliance data. **Name:** user_data, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["TRUE", "FALSE"] ### User Data Path: Required if select "TRUE" in "Use User Data". Please input a valid folder path which contains the user data files. **Name:** user_data_path, **Type:** String, **Units:** , **Required:** false, **Model Dependent:** false ### Use PRM evaluation package Set to True the measure will search the local copy of OpenStudio-Standards to perform PRM **Name:** evaluation_package, **Type:** Choice, **Units:** , **Required:** true, **Model Dependent:** false **Choice Display Names** ["TRUE", "FALSE"] ### Evaluation Package Path: Required if select "TRUE" in "Use PRM evaluation package". Please input a valid folder path which contains the evaluation package. **Name:** evaluation_package_path, **Type:** String, **Units:** , **Required:** false, **Model Dependent:** false ### Generate logs for debug **Name:** debug, **Type:** Boolean, **Units:** , **Required:** true, **Model Dependent:** false