Energy Conservation Measure

OpenStudio Results

Name 
openstudio_results
Display Name 
OpenStudio Results
Class Name 
OpenStudioResults
Version Modified 
20170323T160651Z
Schema Version 
3.0
Rating 
5
Average: 5 (1 vote)
Attributes 
Uses SketchUp APIfalse
Measure TypeReportingMeasure
Intended Software ToolOpenStudio Application
Intended Software ToolParametric Analysis Tool
Intended Software ToolAnalysis Spreadsheet
Intended Use CaseAutomatic Report Generation

Details

DescriptionThis measure creates high level tables and charts pulling both from model inputs and EnergyPlus results. It has building level information as well as detail on space types, thermal zones, HVAC systems, envelope characteristics, and economics. Click the heading above a chart to view a table of the chart data.
Modeler DescriptionFor the most part consumption data comes from the tabular EnergyPlus results, however there are a few requests added for time series results. Space type and loop details come from the OpenStudio model. The code for this is modular, making it easy to use as a template for your own custom reports. The structure of the report uses bootstrap, and the graphs use dimple js.

Measure Arguments

NameDisplay NameShort NameDescriptionUnitsTypeRequiredModel DependentDefault ValueChoicesMin ValueMax Value
building_summary_sectionModel Summary---Booleantruefalsetruetrue
false
--
annual_overview_sectionAnnual Overview---Booleantruefalsetruetrue
false
--
monthly_overview_sectionMonthly Overview---Booleantruefalsetruetrue
false
--
utility_bills_rates_sectionUtility Bills/Rates---Booleantruefalsetruetrue
false
--
envelope_section_sectionEnvelope---Booleantruefalsetruetrue
false
--
space_type_breakdown_sectionSpace Type Breakdown---Booleantruefalsetruetrue
false
--
space_type_details_sectionSpace Type Summary---Booleantruefalsetruetrue
false
--
interior_lighting_sectionInterior Lighting Summary---Booleantruefalsetruetrue
false
--
plug_loads_sectionPlug Loads Summary---Booleantruefalsetruetrue
false
--
exterior_light_sectionExterior Lighting---Booleantruefalsetruetrue
false
--
water_use_sectionWater Use Equipment---Booleantruefalsetruetrue
false
--
hvac_load_profileHVAC Load Profiles---Booleantruefalsetruetrue
false
--
zone_condition_sectionZone Conditions---Booleantruefalsetruetrue
false
--
zone_summary_sectionZone Overview---Booleantruefalsetruetrue
false
--
zone_equipment_detail_sectionZone Equipment Detail---Booleantruefalsetruetrue
false
--
air_loops_detail_sectionAir Loops Detail---Booleantruefalsetruetrue
false
--
plant_loops_detail_sectionPlant Loops Detail---Booleantruefalsetruetrue
false
--
outdoor_air_sectionOutdoor Air---Booleantruefalsetruetrue
false
--
cost_summary_sectionCash Flow---Booleantruefalsetruetrue
false
--
source_energy_sectionSite and Source Summary---Booleantruefalsetruetrue
false
--
schedules_overview_sectionSchedule Overview---Booleantruefalsetruetrue
false
--

Measure Outputs

NameDisplay NameShort NameDescriptionUnitsTypeModel Dependent
electricity_ipelectricity_ipelectricity_ip--Doublefalse
natural_gas_ipnatural_gas_ipnatural_gas_ip--Doublefalse
additional_fuel_ipadditional_fuel_ipadditional_fuel_ip--Doublefalse
district_heating_ipdistrict_heating_ipdistrict_heating_ip--Doublefalse
district_cooling_ipdistrict_cooling_ipdistrict_cooling_ip--Doublefalse
euieuieui--Doublefalse
net_site_energynet_site_energynet_site_energy--Doublefalse
annual_peak_electric_demandannual_peak_electric_demandannual_peak_electric_demand--Doublefalse
unmet_hours_during_occupied_coolingunmet_hours_during_occupied_coolingunmet_hours_during_occupied_cooling--Doublefalse
unmet_hours_during_occupied_heatingunmet_hours_during_occupied_heatingunmet_hours_during_occupied_heating--Doublefalse
first_year_capital_costfirst_year_capital_costfirst_year_capital_cost--Doublefalse
annual_utility_costannual_utility_costannual_utility_cost--Doublefalse
total_lifecycle_costtotal_lifecycle_costtotal_lifecycle_cost--Doublefalse