Search Results

Results 1 to 25 out of 156

Name Type Description Download
ZEDG VRF with DOAS Ruby measure Adds VRF system with multiple indoor units connected to an outdoor unit.
Repo: NREL/openstudio-aedg-gem
download ZEDG VRF with DOAS
ZEDG K12 Insert Ground Domain E+ Kusdua Ruby measure Measure to insert the EnergyPlus Site:GroundDomain:Slab object into the model and, when recommended, horizontal and vertical insulation.
Repo: NREL/openstudio-aedg-gem
download ZEDG K12 Insert Ground Domain E+ Kusdua
AedgK12ElectricEquipment Ruby measure This measure removes all existing electric equipment from spaces recognized as primary or secondary school space types. One exception is that loads assigned directly to a space whre the load definition contains "Elev" or "elev" will be left alone. New electric equipment will be added based on...
Repo: NREL/openstudio-aedg-gem
download AedgK12ElectricEquipment
AedgOfficeHvacWshpDoas Ruby measure Measure replaces existing HVAC system (if any) with a Water Source Heat Pump (WSHP) with DOAS HVAC system (one DOAS per floor). The WSHP with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve...
Repo: NREL/openstudio-aedg-gem
download AedgOfficeHvacWshpDoas
AedgK12ElectricEquipmentControls Ruby measure This measure reduces the values associated with electric equipment schedules to simulate reductions due to equipment controls throughout the building. This includes occupancy based outlets or adapters, as well as network or timer based controls. Kitchen equipment controls are not altered by this...
Repo: NREL/openstudio-aedg-gem
download AedgK12ElectricEquipmentControls
AedgK12EnvelopeAndEntryInfiltration Ruby measure This measure addresses two sources of air infiltration. The first is infiltration through the building envelope. The second is infiltration due to occupants entering and leaving the building. The AEDG provides recommendations and tips on how to limit infiltration in both cases. For occupant...
Repo: NREL/openstudio-aedg-gem
download AedgK12EnvelopeAndEntryInfiltration
AedgK12ExteriorWallConstruction Ruby measure This measure will modify existing exterior wall insulation levels based on construction type and climate zone. The exterior wall construction type and climate zone should be set in the model prior to using this measure. For mass and metal walls if an existing insulation layer can be found it...
Repo: NREL/openstudio-aedg-gem
download AedgK12ExteriorWallConstruction
AedgK12Swh Ruby measure Measure replaces existing swh equipment (if any) with the swh equipment recommendations of the 50% K-12 AEDG.
Repo: NREL/openstudio-aedg-gem
download AedgK12Swh
AedgOfficeHvacAshpDoas Ruby measure Measure replaces existing HVAC system (if any) with an Air Source Heat Pump (ASHP) with DOAS HVAC system (one DOAS per floor). The ASHP with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve...
Repo: NREL/openstudio-aedg-gem
download AedgOfficeHvacAshpDoas
AedgOfficeHvacVavChW Ruby measure Measure replaces existing HVAC system (if any) with a high efficiency multizone variable air volume (VAV) HVAC system (one system per floor). The multizone VAV system (centralized cooling with zone level heating) is applied to all space types. In select cases, the user is given the option to...
Repo: NREL/openstudio-aedg-gem
download AedgOfficeHvacVavChW
AedgOfficeSwh Ruby measure Measure replaces existing swh equipment (if any) with the swh equipment recommendations of the 50% Small and Medium Office AEDG.
Repo: NREL/openstudio-aedg-gem
download AedgOfficeSwh
AedgSmallToMediumOfficeInteriorLightingControls Ruby measure This measure reduces the values associated with lighting schedules to simulate reductions due to vacancy sensors throughout the building.
Repo: NREL/openstudio-aedg-gem
download AedgSmallToMediumOfficeInteriorLightingControls
AedgSmallToMediumOfficeSlabAndBasement Ruby measure This measure applies Small to Medium Office AEDG 50% recommendations for slab and below grade walls. It can also be used to model and simulate ASHRAE 90.1 2004 slab and below grade wall insulation levels. Note that for many climate zones (1-3), if your model doesn't have below grade walls or...
Repo: NREL/openstudio-aedg-gem
download AedgSmallToMediumOfficeSlabAndBasement
ZEDG K12 RoofConstruction Ruby measure ZEDG version, only setup for IEAD roof. This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof type and climate zone should be set in the model prior to using this measure. If your model uses an attic, all...
Repo: NREL/openstudio-aedg-gem
download ZEDG K12 RoofConstruction
AedgK12ExteriorLighting Ruby measure This measure will create exterior lights objects in four different categories described below. The lighting levels and controls will be based on the "How to Implement Recommendations" section in the AEDG; any existing exterior lighting will be removed. A special input is needed for this measure...
Repo: NREL/openstudio-aedg-gem
download AedgK12ExteriorLighting
AedgK12HvacDualDuctDoas Ruby measure Measure replaces existing HVAC system (if any) with a Dual Duct with DOAS HVAC system (one system per floor). The dual duct system (separate variable speed air delivery paths for cooling and DOAS, with zone level heating) is applied to all space types except Cafeteria, Kitchen, Gym, and...
Repo: NREL/openstudio-aedg-gem
download AedgK12HvacDualDuctDoas
AedgK12HvacFanCoilDoas Ruby measure Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types except Cafeteria, Kitchen, Gym, and Auditorium; packaged single zone equipment...
Repo: NREL/openstudio-aedg-gem
download AedgK12HvacFanCoilDoas
AedgK12HvacGshpDoas Ruby measure Measure replaces existing HVAC system (if any) with a Ground Source Heat Pump (GSHP) with DOAS HVAC system (one DOAS per floor). The GSHP with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types except Cafeteria, Kitchen, Gym, and Auditorium; packaged...
Repo: NREL/openstudio-aedg-gem
download AedgK12HvacGshpDoas
AedgK12RoofConstruction Ruby measure This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof type and climate zone should be set in the model prior to using this measure. If your model uses an attic, all attic surfaces should have an "Attic'...
Repo: NREL/openstudio-aedg-gem
download AedgK12RoofConstruction
AedgSmallToMediumOfficeExteriorDoorConstruction Ruby measure This measure is intended for use on opaque doors; if doors are glass they should be treated as windows. OpenStudio does have a unique object for overhead doors versus standard doors. This measure doesn't alter infiltration. There is a separate measure for infiltration that includes user...
Repo: NREL/openstudio-aedg-gem
download AedgSmallToMediumOfficeExteriorDoorConstruction
AedgSmallToMediumOfficeExteriorFloorConstruction Ruby measure This measure will modify existing exterior floor (air exposed) insulation levels based on construction type and climate zone. The exterior floor construction type and climate zone should be set in the model prior to using this measure. For mass floors if an existing insulation layer can be found...
Repo: NREL/openstudio-aedg-gem
download AedgSmallToMediumOfficeExteriorFloorConstruction
AedgSmallToMediumOfficeRoofConstruction Ruby measure This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof type and climate zone should be set in the model prior to using this measure. If your model uses an attic, all attic surfaces should have an "Attic'...
Repo: NREL/openstudio-aedg-gem
download AedgSmallToMediumOfficeRoofConstruction
ZEDG K12 Interior Lighting Ruby measure This measure removes all existing electric equipment objects from spaces recognized as primary or secondary school space types, with the exception of the kitchen which has a dedicated measure that should be used. New equipment will be added based on the Net Zero K12 recommendations.
Repo: NREL/openstudio-aedg-gem
download ZEDG K12 Interior Lighting
AedgK12ExteriorDoorConstruction Ruby measure This measure is intended for use on opaque doors; if doors are glass they should be treated as windows. OpenStudio does have a unique object for overhead doors versus standard doors. This measure doesn't alter infiltration. There is a separate measure for infiltration that includes user...
Repo: NREL/openstudio-aedg-gem
download AedgK12ExteriorDoorConstruction
AedgK12ExteriorFloorConstruction Ruby measure This measure will modify existing exterior floor (air exposed) insulation levels based on construction type and climate zone. The exterior floor construction type and climate zone should be set in the model prior to using this measure. For mass floors if an existing insulation layer can be found...
Repo: NREL/openstudio-aedg-gem
download AedgK12ExteriorFloorConstruction