189.1-2009 Nonres 1A Attic Floor
189.1-2009 Nonres 1A Attic Floor
Effective R-value6.502
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic Floor
ConstructionAttic Floor
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Door Non-Swinging
189.1-2009 Nonres 1A Door Non-Swinging
Effective R-value0.3521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R
Construction TypeNon-Swinging
ConstructionDoor
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 1A Door Swinging
189.1-2009 Nonres 1A Door Swinging
Effective R-value0.2932
Film Coefficientsfalse
Construction TypeSwinging
ConstructionDoor
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 1A Exposed Floor Mass
189.1-2009 Nonres 1A Exposed Floor Mass
Effective R-value1.04
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-4.2 ci
Construction TypeMass
ConstructionExposed Floor
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Slab Unheated- 4in Slab without Carpet
189.1-2009 Nonres 1A Ext Slab Unheated- 4in Slab without Carpet
Effective R-value0.07752
Film Coefficientsfalse
Construction TypeUnheated- 4in Slab without Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Slab Unheated- 4in Slab with Carpet
189.1-2009 Nonres 1A Ext Slab Unheated- 4in Slab with Carpet
Effective R-value0.2939
Film Coefficientsfalse
Construction TypeUnheated- 4in Slab with Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Slab Unheated- 8in Slab without Carpet
189.1-2009 Nonres 1A Ext Slab Unheated- 8in Slab without Carpet
Effective R-value0.155
Film Coefficientsfalse
Construction TypeUnheated- 8in Slab without Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Slab Unheated- 8in Slab with Carpet
189.1-2009 Nonres 1A Ext Slab Unheated- 8in Slab with Carpet
Effective R-value0.3715
Film Coefficientsfalse
Construction TypeUnheated- 8in Slab with Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Wall Mass
189.1-2009 Nonres 1A Ext Wall Mass
Effective R-value1.014
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-5.7 ci
Construction TypeMass
ConstructionExterior Wall
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Wall Metal Building
189.1-2009 Nonres 1A Ext Wall Metal Building
Effective R-value2.073
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-5 + R-6.5 ci
Construction TypeMetal Building
ConstructionExterior Wall
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Wall Steel-Framed
189.1-2009 Nonres 1A Ext Wall Steel-Framed
Effective R-value2.179
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-5.0 ci
Construction TypeSteel-Framed
ConstructionExterior Wall
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Ext Wall Wood-Framed and Other
189.1-2009 Nonres 1A Ext Wall Wood-Framed and Other
Effective R-value2.624
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-3.8 ci
Construction TypeWood-Framed and Other
ConstructionExterior Wall
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Int Wall
189.1-2009 Nonres 1A Int Wall
Construction TypeStandard
Film Coefficientsfalse
ConstructionInterior Wall
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Roof Attic and Other
189.1-2009 Nonres 1A Roof Attic and Other
Effective R-value6.443
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Roof IEAD
189.1-2009 Nonres 1A Roof IEAD
Effective R-value3.515
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Roof Metal Building
189.1-2009 Nonres 1A Roof Metal Building
Effective R-value3.812
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19 + R-11 Ls
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 1A Skylight without Curb
189.1-2009 Nonres 1A Skylight without Curb
Overall U-factor3.241
SHGC0.19
VLT0.241
Minimum Glazing Fraction0
Maximum Glazing Fraction0.02
Construction TypeAll Skylights without Curb
ConstructionSkylight
FacadeSkylight
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 1A Window Metal framing all other
189.1-2009 Nonres 1A Window Metal framing all other
Overall U-factor6.809
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeMetal framing (all other)
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 1A Window Metal framing curtainwall-storefront
189.1-2009 Nonres 1A Window Metal framing curtainwall-storefront
Overall U-factor6.809
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeMetal framing (curtainwall/storefront)
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 1A Window Metal framing entrance door
189.1-2009 Nonres 1A Window Metal framing entrance door
Overall U-factor6.809
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeMetal framing (entrance door)
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 1A Window Nonmetal framing
189.1-2009 Nonres 1A Window Nonmetal framing
Overall U-factor6.809
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeNonmetal framing
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Attic Floor
189.1-2009 Nonres 2A Attic Floor
Effective R-value8.163
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-49
Construction TypeAttic Floor
ConstructionAttic Floor
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Door Non-Swinging
189.1-2009 Nonres 2A Door Non-Swinging
Effective R-value0.3521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R
Construction TypeNon-Swinging
ConstructionDoor
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Door Swinging
189.1-2009 Nonres 2A Door Swinging
Effective R-value0.2932
Film Coefficientsfalse
Construction TypeSwinging
ConstructionDoor
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Exposed Floor Mass
189.1-2009 Nonres 2A Exposed Floor Mass
Effective R-value1.397
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-6.3 ci
Construction TypeMass
ConstructionExposed Floor
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Slab Unheated- 4in Slab without Carpet
189.1-2009 Nonres 2A Ext Slab Unheated- 4in Slab without Carpet
Effective R-value0.07752
Film Coefficientsfalse
Construction TypeUnheated- 4in Slab without Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Slab Unheated- 4in Slab with Carpet
189.1-2009 Nonres 2A Ext Slab Unheated- 4in Slab with Carpet
Effective R-value0.2939
Film Coefficientsfalse
Construction TypeUnheated- 4in Slab with Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Slab Unheated- 8in Slab without Carpet
189.1-2009 Nonres 2A Ext Slab Unheated- 8in Slab without Carpet
Effective R-value0.155
Film Coefficientsfalse
Construction TypeUnheated- 8in Slab without Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Slab Unheated- 8in Slab with Carpet
189.1-2009 Nonres 2A Ext Slab Unheated- 8in Slab with Carpet
Effective R-value0.3715
Film Coefficientsfalse
Construction TypeUnheated- 8in Slab with Carpet
ConstructionExterior Slab
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Wall Mass
189.1-2009 Nonres 2A Ext Wall Mass
Effective R-value1.28
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-7.6 ci
Construction TypeMass
ConstructionExterior Wall
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Wall Metal Building
189.1-2009 Nonres 2A Ext Wall Metal Building
Effective R-value2.073
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-6.5 ci
Construction TypeMetal Building
ConstructionExterior Wall
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Wall Steel-Framed
189.1-2009 Nonres 2A Ext Wall Steel-Framed
Effective R-value2.179
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-5.0 ci
Construction TypeSteel-Framed
ConstructionExterior Wall
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Ext Wall Wood-Framed and Other
189.1-2009 Nonres 2A Ext Wall Wood-Framed and Other
Effective R-value2.624
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-3.8 ci
Construction TypeWood-Framed and Other
ConstructionExterior Wall
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Int Wall
189.1-2009 Nonres 2A Int Wall
Construction TypeStandard
Film Coefficientsfalse
ConstructionInterior Wall
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Roof Attic and Other
189.1-2009 Nonres 2A Roof Attic and Other
Effective R-value8.104
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-49
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Roof IEAD
189.1-2009 Nonres 2A Roof IEAD
Effective R-value4.355
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-25 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Roof Metal Building
189.1-2009 Nonres 2A Roof Metal Building
Effective R-value4.812
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19 + R-11 Ls
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 2A Skylight without Curb
189.1-2009 Nonres 2A Skylight without Curb
Overall U-factor3.241
SHGC0.19
VLT0.241
Minimum Glazing Fraction0
Maximum Glazing Fraction0.02
Construction TypeAll Skylights without Curb
ConstructionSkylight
FacadeSkylight
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Window Metal framing all other
189.1-2009 Nonres 2A Window Metal framing all other
Overall U-factor4.26
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeMetal framing (all other)
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Window Metal framing curtainwall-storefront
189.1-2009 Nonres 2A Window Metal framing curtainwall-storefront
Overall U-factor3.971
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeMetal framing (curtainwall/storefront)
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Window Metal framing entrance door
189.1-2009 Nonres 2A Window Metal framing entrance door
Overall U-factor6.247
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeMetal framing (entrance door)
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 2A Window Nonmetal framing
189.1-2009 Nonres 2A Window Nonmetal framing
Overall U-factor4.26
SHGC0.25
VLT0.25
Minimum Glazing Fraction0
Maximum Glazing Fraction0.4
Construction TypeNonmetal framing
ConstructionWindow
FacadeEast
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
11/13/2013 Download Component
189.1-2009 Nonres 3A Attic Floor
189.1-2009 Nonres 3A Attic Floor
Effective R-value8.163
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-49
Construction TypeAttic Floor
ConstructionAttic Floor
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Ext Wall Mass
189.1-2009 Nonres 3A Ext Wall Mass
Effective R-value1.545
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-9.5 ci
Construction TypeMass
ConstructionExterior Wall
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Ext Wall Metal Building
189.1-2009 Nonres 3A Ext Wall Metal Building
Effective R-value2.073
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-6.5 ci
Construction TypeMetal Building
ConstructionExterior Wall
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Ext Wall Steel-Framed
189.1-2009 Nonres 3A Ext Wall Steel-Framed
Effective R-value2.179
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-5.0 ci
Construction TypeSteel-Framed
ConstructionExterior Wall
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Ext Wall Wood-Framed and Other
189.1-2009 Nonres 3A Ext Wall Wood-Framed and Other
Effective R-value2.624
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-3.8 ci
Construction TypeWood-Framed and Other
ConstructionExterior Wall
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Int Wall
189.1-2009 Nonres 3A Int Wall
Construction TypeStandard
Film Coefficientsfalse
ConstructionInterior Wall
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Roof Attic and Other
189.1-2009 Nonres 3A Roof Attic and Other
Effective R-value8.104
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-49
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component
189.1-2009 Nonres 3A Roof IEAD
189.1-2009 Nonres 3A Roof IEAD
Effective R-value4.355
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-25 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE Std189
Standard TypeNonresidential
04/01/2013 Download Component