Skip to main content area
Building Component Library
Login
Welcome, Guest!
Search form
Search
Sort by
Relevancy
Title
Type
Author
Date
Filter by type
Component (123)
Apply Component filter
Filter by tags
(-)
Remove Electric Lighting filter
Electric Lighting
Lamps (86)
Apply Lamps filter
Non-SSL Lamps (86)
Apply Non-SSL Lamps filter
Lamp Ballasts (37)
Apply Lamp Ballasts filter
Filter by group
NREL (123)
Apply NREL filter
Filter by attributes
Search results
Enter terms
Generic BT37 HID Electronic Ballast 150 W
Generic BT37 HID Electronic Ballast 150 W
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Directional
ANSI Lamp Designation
BT37
Ballast Type
HID Electronic
Starting Method
Program Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic BT37 HID Electronic Ballast 250 W
Generic BT37 HID Electronic Ballast 250 W
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Directional
ANSI Lamp Designation
BT37
Ballast Type
HID Electronic
Starting Method
Program Start
Input Voltage
120- 480
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic BT37 HID Magnetic Ballast 150 W
Generic BT37 HID Magnetic Ballast 150 W
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.9
Input Power Factor at 277V
0.9
Lamp Distribution Type
Directional
ANSI Lamp Designation
BT37
Ballast Type
HID Magnetic
Starting Method
Program Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic BT56 HID Electronic Ballast 1000 W
Generic BT56 HID Electronic Ballast 1000 W
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Directional
ANSI Lamp Designation
BT56
Ballast Type
HID Electronic
Starting Method
Program Start
Input Voltage
120- 480
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic BT56 HID Magnetic Ballast 1000 W
Generic BT56 HID Magnetic Ballast 1000 W
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.9
Input Power Factor at 277V
0.9
Lamp Distribution Type
Directional
ANSI Lamp Designation
BT56
Ballast Type
HID Magnetic
Starting Method
Program Start
Input Voltage
120- 480
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 1 lamp
Generic T12 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 1 lamp
Ballast Factor
0.88
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Electronic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 2 lamp
Generic T12 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 2 lamp
Ballast Factor
0.88
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Electronic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Electronic Non-Dimming Ballast- Ballast Factor 0.88- 2 lamp
Generic T12 Fluorescent Electronic Non-Dimming Ballast- Ballast Factor 0.88- 2 lamp
Ballast Factor
0.88
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Electronic Non-Dimming Ballast- Ballast Factor 0.88- 4 lamp
Generic T12 Fluorescent Electronic Non-Dimming Ballast- Ballast Factor 0.88- 4 lamp
Ballast Factor
0.88
Number of Lamps
4
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Magnetic Dimming Ballast- Ballast Factor 1.2- 2 lamp
Generic T12 Fluorescent Magnetic Dimming Ballast- Ballast Factor 1.2- 2 lamp
Ballast Factor
1.2
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Magnetic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 1 lamp
Generic T12 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 1 lamp
Ballast Factor
1.2
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Magnetic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 2 lamp
Generic T12 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 2 lamp
Ballast Factor
1.2
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Magnetic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T12 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 4 lamp
Generic T12 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 4 lamp
Ballast Factor
1.2
Number of Lamps
4
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Magnetic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 1 lamp
Generic T8 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 1 lamp
Ballast Factor
0.88
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 4 lamp
Generic T8 Fluorescent Electronic Dimming Ballast- Ballast Factor 0.88- 4 lamp
Ballast Factor
0.88
Number of Lamps
4
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Electronic Non-Dimming Ballast- Ballast Factor 0.88- 2 lamp
Generic T8 Fluorescent Electronic Non-Dimming Ballast- Ballast Factor 0.88- 2 lamp
Ballast Factor
0.88
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Magnetic Dimming Ballast- Ballast Factor 1.2- 1 lamp
Generic T8 Fluorescent Magnetic Dimming Ballast- Ballast Factor 1.2- 1 lamp
Ballast Factor
1.2
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Magnetic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Magnetic Dimming Ballast- Ballast Factor 1.2- 2 lamp
Generic T8 Fluorescent Magnetic Dimming Ballast- Ballast Factor 1.2- 2 lamp
Ballast Factor
1.2
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Magnetic Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 1 lamp
Generic T8 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 1 lamp
Ballast Factor
1.2
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Magnetic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic T8 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 2 lamp
Generic T8 Fluorescent Magnetic Non-Dimming Ballast- Ballast Factor 1.2- 2 lamp
Ballast Factor
1.2
Number of Lamps
2
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Magnetic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Instant Start Fluorescent Electronic Non-Dimming Ballast 1 lamp- A-132-IP-UNV
Instant Start Fluorescent Electronic Non-Dimming Ballast 1 lamp- A-132-IP-UNV
Ballast Factor
0.87
Number of Lamps
1
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Instant Start Fluorescent Electronic Non-Dimming Ballast 1 lamp- ICN-2P32-N
Instant Start Fluorescent Electronic Non-Dimming Ballast 1 lamp- ICN-2P32-N
Ballast Factor
1.03
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Instant Start Fluorescent Electronic Non-Dimming Ballast 2 lamp- A-232-IP-UNV
Instant Start Fluorescent Electronic Non-Dimming Ballast 2 lamp- A-232-IP-UNV
Ballast Factor
0.88
Number of Lamps
2
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Instant Start Fluorescent Electronic Non-Dimming Ballast 3 lamp- A-332-IP-UNV
Instant Start Fluorescent Electronic Non-Dimming Ballast 3 lamp- A-332-IP-UNV
Ballast Factor
0.88
Number of Lamps
3
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Instant Start Fluorescent Electronic Non-Dimming Ballast 4 lamp- A-432-IP-UNV
Instant Start Fluorescent Electronic Non-Dimming Ballast 4 lamp- A-432-IP-UNV
Ballast Factor
0.88
Number of Lamps
4
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Instant Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Instant Start Fluorescent Electronic Non-Dimming Ballast-ICN-1P32-N
Instant Start Fluorescent Electronic Non-Dimming Ballast-ICN-1P32-N
Ballast Factor
0.88
Number of Lamps
1
Input Power Factor at 120V
0.99
Input Power Factor at 277V
0.99
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Non-Dimming
Input Power at 120V
only need to fill in the column corresp. To the input voltage
Starting Method
Instant Start
Input Voltage
120- 277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Program Start Fluorescent Electronic Dimming Ballast-CFM32W-GX24Q
Program Start Fluorescent Electronic Dimming Ballast-CFM32W-GX24Q
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T8
Ballast Type
Fluorescent Electronic Dimming
Starting Method
Program Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Rapid Start Fluorescent Magnetic Non-Dimming Ballast-R4S40ATPAC
Rapid Start Fluorescent Magnetic Non-Dimming Ballast-R4S40ATPAC
Ballast Factor
0.97
Number of Lamps
1
Input Power Factor at 120V
0.88
Input Power Factor at 277V
0.88
Lamp Distribution Type
Linear
ANSI Lamp Designation
T12
Ballast Type
Fluorescent Magnetic Non-Dimming
Starting Method
Rapid Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Program Start Fluorescent Electronic Non-Dimming Ballast-F14T5
Program Start Fluorescent Electronic Non-Dimming Ballast-F14T5
Ballast Factor
1.06
Number of Lamps
2
Input Power Factor at 120V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T5
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Program Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Program Start Fluorescent Electronic Non-Dimming Ballast-F21T5
Program Start Fluorescent Electronic Non-Dimming Ballast-F21T5
Ballast Factor
1.15
Number of Lamps
2
Input Power Factor at 120V
0.98
Input Power Factor at 277V
0.98
Lamp Distribution Type
Linear
ANSI Lamp Designation
T5
Ballast Type
Fluorescent Electronic Non-Dimming
Starting Method
Program Start
Input Voltage
120-277
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Rapid Start HID Magnetic Ballast-71A7707
Rapid Start HID Magnetic Ballast-71A7707
Ballast Factor
1
Number of Lamps
1
Input Power Factor at 120V
0.9
Lamp Distribution Type
Omnidirectional
ANSI Lamp Designation
ED18
Ballast Type
HID Magnetic
Starting Method
Rapid Start
Input Voltage
120.0
Lamp Ballasts
Electric Lighting
11/26/2013
NREL
Generic 26W Compact Fluorescent
Generic 26W Compact Fluorescent
Input Power
26
Mean Luminous Flux
1700
Correlated Color Temperature
4100
Color Rendering Index
84
Integral Ballast
true
Light Source Type
Compact Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
11/26/2013
NREL
Generic A19 100W Standard Incandescent
Generic A19 100W Standard Incandescent
Input Power
100
Mean Luminous Flux
1340
Color Rendering Index
100
Integral Ballast
false
ANSI Lamp Designation
A19
Light Source Type
Standard Incandescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic A19 60W Standard Incandescent
Generic A19 60W Standard Incandescent
Input Power
60
Color Rendering Index
100
Integral Ballast
false
ANSI Lamp Designation
A19
Light Source Type
Standard Incandescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic ED18 250W High Pressure Sodium
Generic ED18 250W High Pressure Sodium
Input Power
250
Mean Luminous Flux
28500
Correlated Color Temperature
2100
Color Rendering Index
21
Integral Ballast
false
ANSI Lamp Designation
ED18
Light Source Type
High Pressure Sodium
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic EL/mDT 13W Compact Fluorescent
Generic EL/mDT 13W Compact Fluorescent
Input Power
13
Mean Luminous Flux
900
Correlated Color Temperature
2700
Color Rendering Index
82
Integral Ballast
true
ANSI Lamp Designation
EL/mDT
Light Source Type
Compact Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic PAR20 50W Halogen
Generic PAR20 50W Halogen
Input Power
50
Mean Luminous Flux
530
Correlated Color Temperature
2900
Color Rendering Index
100
Integral Ballast
false
ANSI Lamp Designation
PAR20
Light Source Type
Halogen
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic PAR38 60W Halogen
Generic PAR38 60W Halogen
Input Power
60
Mean Luminous Flux
1145
Correlated Color Temperature
2770
Color Rendering Index
100
Integral Ballast
false
ANSI Lamp Designation
PAR38
Light Source Type
Halogen
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T12 40W Linear Fluorescent
Generic T12 40W Linear Fluorescent
Input Power
40
Mean Luminous Flux
2200
Correlated Color Temperature
5000
Color Rendering Index
90
Integral Ballast
false
ANSI Lamp Designation
T12
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T13 34W Linear Fluorescent
Generic T13 34W Linear Fluorescent
Input Power
34
Mean Luminous Flux
2600
Correlated Color Temperature
4200
Color Rendering Index
60
Integral Ballast
false
ANSI Lamp Designation
T13
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T4 13W Fluorescent
Generic T4 13W Fluorescent
Input Power
13
Mean Luminous Flux
827
Correlated Color Temperature
2700
Color Rendering Index
82
Integral Ballast
false
ANSI Lamp Designation
T4
Light Source Type
Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T5 54W Linear Fluorescent
Generic T5 54W Linear Fluorescent
Input Power
54
Mean Luminous Flux
3500
Correlated Color Temperature
5000
Color Rendering Index
85
Integral Ballast
false
ANSI Lamp Designation
T5
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T8 25W Linear Fluorescent
Generic T8 25W Linear Fluorescent
Input Power
25
Mean Luminous Flux
2250
Correlated Color Temperature
3500
Color Rendering Index
85
Integral Ballast
false
ANSI Lamp Designation
T8
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T8 32W Linear Fluorescent
Generic T8 32W Linear Fluorescent
Input Power
32
Mean Luminous Flux
2950
Correlated Color Temperature
3500
Color Rendering Index
82
Integral Ballast
false
ANSI Lamp Designation
T8
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Generic T9 32W Linear Fluorescent
Generic T9 32W Linear Fluorescent
Input Power
32
Mean Luminous Flux
2850
Correlated Color Temperature
4100
Color Rendering Index
78
Integral Ballast
false
ANSI Lamp Designation
T9
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Philips Fluorescent T4-PL-S ALTO 13W/827 GX23/2P CT
Philips Fluorescent T4-PL-S ALTO 13W/827 GX23/2P CT
Input Power
13
Mean Luminous Flux
827
Correlated Color Temperature
2700
Color Rendering Index
82
Integral Ballast
false
ANSI Lamp Designation
T4
Light Source Type
Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Philips Halogen PAR20-50W 120V PAR20 FL 25D 1CT
Philips Halogen PAR20-50W 120V PAR20 FL 25D 1CT
Input Power
50
Mean Luminous Flux
530
Correlated Color Temperature
2900
Color Rendering Index
100
Integral Ballast
false
ANSI Lamp Designation
PAR20
Light Source Type
Halogen
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Philips Halogen PAR38-60W 120V PAR38 SP 10D CL 1CT
Philips Halogen PAR38-60W 120V PAR38 SP 10D CL 1CT
Input Power
60
Mean Luminous Flux
1145
Correlated Color Temperature
2770
Color Rendering Index
100
Integral Ballast
false
ANSI Lamp Designation
PAR38
Light Source Type
Halogen
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Philips Linear Fluorescent T5-F39T5/850 HO ALTO
Philips Linear Fluorescent T5-F39T5/850 HO ALTO
Input Power
54
Mean Luminous Flux
3500
Correlated Color Temperature
5000
Color Rendering Index
85
Integral Ballast
false
ANSI Lamp Designation
T5
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Philips Linear Fluorescent T8-F25T8 ADV830 ALTO
Philips Linear Fluorescent T8-F25T8 ADV830 ALTO
Input Power
25
Mean Luminous Flux
2250
Correlated Color Temperature
3500
Color Rendering Index
85
Integral Ballast
false
ANSI Lamp Designation
T8
Light Source Type
Linear Fluorescent
Non-SSL Lamps
Lamps
Electric Lighting
02/15/2014
NREL
Pages
1
2
3
next ›
last »