Filter by type
Component (576)
Apply Component filter
Filter by tags
(-)
Remove Construction Assembly filter
Construction Assembly
(-)
Remove Roof Ceiling filter
Roof Ceiling
Exterior Roof (384)
Apply Exterior Roof filter
Attic Roof (192)
Apply Attic Roof filter
Filter by attributes
Climate Zone
ASHRAE 2004:1A
ASHRAE 2004:1B
ASHRAE 2004:2A
ASHRAE 2004:2B
ASHRAE 2004:3A
ASHRAE 2004:3B
ASHRAE 2004:3C
ASHRAE 2004:4A
ASHRAE 2004:4B
ASHRAE 2004:4C
ASHRAE 2004:5A
ASHRAE 2004:5B
ASHRAE 2004:5C
ASHRAE 2004:6A
ASHRAE 2004:6B
ASHRAE 2004:7A
ASHRAE 2004:7B
ASHRAE 2004:8A
ASHRAE 2004:8B
ASHRAE 1999:B-1
ASHRAE 1999:B-10
ASHRAE 1999:B-11
ASHRAE 1999:B-12
ASHRAE 1999:B-13
ASHRAE 1999:B-14
ASHRAE 1999:B-15
ASHRAE 1999:B-16
ASHRAE 1999:B-17
ASHRAE 1999:B-18
ASHRAE 1999:B-19
ASHRAE 1999:B-2
ASHRAE 1999:B-20
ASHRAE 1999:B-21
ASHRAE 1999:B-22
ASHRAE 1999:B-23
ASHRAE 1999:B-24
ASHRAE 1999:B-25
ASHRAE 1999:B-26
ASHRAE 1999:B-3
ASHRAE 1999:B-4
ASHRAE 1999:B-5
ASHRAE 1999:B-6
ASHRAE 1999:B-7
ASHRAE 1999:B-8
ASHRAE 1999:B-9
CEC 2005:10
CEC 2005:11
CEC 2005:12
CEC 2005:13
CEC 2005:2
Search results
Enter terms
90.1-1999 Res B18 Roof Attic and Other
90.1-1999 Res B18 Roof Attic and Other
Effective R-value
4.968
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-30
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-18
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B18 Roof IEAD
90.1-1999 Res B18 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-18
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B18 Roof Metal Building
90.1-1999 Res B18 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-18
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B19 Roof Attic and Other
90.1-1999 Res B19 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-19
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B19 Roof IEAD
90.1-1999 Res B19 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-19
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B19 Roof Metal Building
90.1-1999 Res B19 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-19
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B1 Roof Attic and Other
90.1-1999 Res B1 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-1
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B1 Roof IEAD
90.1-1999 Res B1 Roof IEAD
Effective R-value
3.481
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-20 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-1
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B1 Roof Metal Building
90.1-1999 Res B1 Roof Metal Building
Effective R-value
3.014
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-13.0 + R-13.0
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-1
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B20 Roof Attic and Other
90.1-1999 Res B20 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-20
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B20 Roof IEAD
90.1-1999 Res B20 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-20
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B20 Roof Metal Building
90.1-1999 Res B20 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-20
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B21 Roof Attic and Other
90.1-1999 Res B21 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-21
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B21 Roof IEAD
90.1-1999 Res B21 Roof IEAD
Effective R-value
3.481
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-20 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-21
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B21 Roof Metal Building
90.1-1999 Res B21 Roof Metal Building
Effective R-value
3.014
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-13.0 + R-13.0
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-21
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B22 Roof Attic and Other
90.1-1999 Res B22 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-22
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B22 Roof IEAD
90.1-1999 Res B22 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-22
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B22 Roof Metal Building
90.1-1999 Res B22 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-22
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B23 Roof Attic and Other
90.1-1999 Res B23 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-23
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B23 Roof IEAD
90.1-1999 Res B23 Roof IEAD
Effective R-value
3.481
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-20 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-23
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B23 Roof Metal Building
90.1-1999 Res B23 Roof Metal Building
Effective R-value
3.014
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-13 + R-13
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-23
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B24 Roof Attic and Other
90.1-1999 Res B24 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-24
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B24 Roof IEAD
90.1-1999 Res B24 Roof IEAD
Effective R-value
3.479
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-20 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-24
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B24 Roof Metal Building
90.1-1999 Res B24 Roof Metal Building
Effective R-value
3.406
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-13 + R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-24
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B25 Roof Attic and Other
90.1-1999 Res B25 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-25
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B25 Roof IEAD
90.1-1999 Res B25 Roof IEAD
Effective R-value
3.479
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-20 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-25
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B25 Roof Metal Building
90.1-1999 Res B25 Roof Metal Building
Effective R-value
3.406
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-13 + R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-25
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B26 Roof Attic and Other
90.1-1999 Res B26 Roof Attic and Other
Effective R-value
10.12
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-60
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-26
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B26 Roof IEAD
90.1-1999 Res B26 Roof IEAD
Effective R-value
4.325
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-25 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-26
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B26 Roof Metal Building
90.1-1999 Res B26 Roof Metal Building
Effective R-value
3.559
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-16 + R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-26
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B2 Roof Attic and Other
90.1-1999 Res B2 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-2
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B2 Roof IEAD
90.1-1999 Res B2 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-2
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B2 Roof Metal Building
90.1-1999 Res B2 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-2
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B3 Roof Attic and Other
90.1-1999 Res B3 Roof Attic and Other
Effective R-value
4.968
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-30
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-3
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B3 Roof IEAD
90.1-1999 Res B3 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-3
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B3 Roof Metal Building
90.1-1999 Res B3 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-3
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B4 Roof Attic and Other
90.1-1999 Res B4 Roof Attic and Other
Effective R-value
4.968
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-30
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-4
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B4 Roof IEAD
90.1-1999 Res B4 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-4
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B4 Roof Metal Building
90.1-1999 Res B4 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-4
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B5 Roof Attic and Other
90.1-1999 Res B5 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-5
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B5 Roof IEAD
90.1-1999 Res B5 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-5
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B5 Roof Metal Building
90.1-1999 Res B5 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-5
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B6 Roof Attic and Other
90.1-1999 Res B6 Roof Attic and Other
Effective R-value
4.968
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-30
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-6
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B6 Roof IEAD
90.1-1999 Res B6 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-6
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B6 Roof Metal Building
90.1-1999 Res B6 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-6
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B7 Roof Attic and Other
90.1-1999 Res B7 Roof Attic and Other
Effective R-value
4.968
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-30
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-7
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B7 Roof IEAD
90.1-1999 Res B7 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-7
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B7 Roof Metal Building
90.1-1999 Res B7 Roof Metal Building
Effective R-value
2.521
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-19
Construction Type
Metal Building
Construction
Roof
Climate Zone
ASHRAE 1999:B-7
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B8 Roof Attic and Other
90.1-1999 Res B8 Roof Attic and Other
Effective R-value
6.297
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-38
Construction Type
Attic and Other
Construction
Roof
Climate Zone
ASHRAE 1999:B-8
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Attic Roof
Roof Ceiling
Construction Assembly
11/01/2013
90.1-1999 Res B8 Roof IEAD
90.1-1999 Res B8 Roof IEAD
Effective R-value
2.61
Film Coefficients
false
Insulation Minimum R-value (ft^2 F h/Btu)
R-15 ci
Construction Type
Insulation Entirely Above Deck
Construction
Roof
Climate Zone
ASHRAE 1999:B-8
OpenStudio Type
OS:Construction
Standard
ASHRAE 90.1-1999
Standard Type
Residential
Exterior Roof
Roof Ceiling
Construction Assembly
11/01/2013