Search results

90.1-2004 Res 4B Roof IEAD
90.1-2004 Res 4B Roof IEAD
Effective R-value2.61
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-15 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 4B Roof Metal Building
90.1-2004 Res 4B Roof Metal Building
Effective R-value2.521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 5B Roof Attic and Other
90.1-2004 Res 5B Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:5B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 5B Roof IEAD
90.1-2004 Res 5B Roof IEAD
Effective R-value2.61
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-15 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:5B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 5B Roof Metal Building
90.1-2004 Res 5B Roof Metal Building
Effective R-value2.521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:5B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 6B Roof Attic and Other
90.1-2004 Res 6B Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:6B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 6B Roof IEAD
90.1-2004 Res 6B Roof IEAD
Effective R-value2.61
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-15 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:6B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 6B Roof Metal Building
90.1-2004 Res 6B Roof Metal Building
Effective R-value2.521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:6B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 7A Roof Attic and Other
90.1-2004 Res 7A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:7A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 7A Roof IEAD
90.1-2004 Res 7A Roof IEAD
Effective R-value2.61
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-15 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:7A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 7A Roof Metal Building
90.1-2004 Res 7A Roof Metal Building
Effective R-value2.521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:7A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 8A Roof Attic and Other
90.1-2004 Res 8A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:8A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 8A Roof IEAD
90.1-2004 Res 8A Roof IEAD
Effective R-value3.479
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:8A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2004 Res 8A Roof Metal Building
90.1-2004 Res 8A Roof Metal Building
Effective R-value3.406
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:8A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2004
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Nonres 1A Roof Attic and Other
90.1-2007 Nonres 1A Roof Attic and Other
Effective R-value4.99
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-30
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 1A Roof IEAD
90.1-2007 Nonres 1A Roof IEAD
Effective R-value2.61
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-15 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 1A Roof Metal Building
90.1-2007 Nonres 1A Roof Metal Building
Effective R-value2.521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 2A Roof Attic and Other
90.1-2007 Nonres 2A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 2A Roof IEAD
90.1-2007 Nonres 2A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 2A Roof Metal Building
90.1-2007 Nonres 2A Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 3A Roof Attic and Other
90.1-2007 Nonres 3A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 3A Roof IEAD
90.1-2007 Nonres 3A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 3A Roof Metal Building
90.1-2007 Nonres 3A Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 4B Roof Attic and Other
90.1-2007 Nonres 4B Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 4B Roof IEAD
90.1-2007 Nonres 4B Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 4B Roof Metal Building
90.1-2007 Nonres 4B Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 5B Roof Attic and Other
90.1-2007 Nonres 5B Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:5B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 5B Roof IEAD
90.1-2007 Nonres 5B Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:5B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 5B Roof Metal Building
90.1-2007 Nonres 5B Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:5B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 6B Roof Attic and Other
90.1-2007 Nonres 6B Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:6B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 6B Roof IEAD
90.1-2007 Nonres 6B Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:6B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 6B Roof Metal Building
90.1-2007 Nonres 6B Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:6B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 7A Roof Attic and Other
90.1-2007 Nonres 7A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:7A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 7A Roof IEAD
90.1-2007 Nonres 7A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:7A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 7A Roof Metal Building
90.1-2007 Nonres 7A Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:7A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 8A Roof Attic and Other
90.1-2007 Nonres 8A Roof Attic and Other
Effective R-value8.17
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-49
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:8A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 8A Roof IEAD
90.1-2007 Nonres 8A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:8A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Nonres 8A Roof Metal Building
90.1-2007 Nonres 8A Roof Metal Building
Effective R-value3.409
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-13 + R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:8A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeNonresidential
11/01/2013 Download Component
90.1-2007 Res 1A Roof Attic and Other
90.1-2007 Res 1A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 1A Roof IEAD
90.1-2007 Res 1A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 1A Roof Metal Building
90.1-2007 Res 1A Roof Metal Building
Effective R-value2.521
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:1A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 2A Roof Attic and Other
90.1-2007 Res 2A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 2A Roof IEAD
90.1-2007 Res 2A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 2A Roof Metal Building
90.1-2007 Res 2A Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:2A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 3A Roof Attic and Other
90.1-2007 Res 3A Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 3A Roof IEAD
90.1-2007 Res 3A Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 3A Roof Metal Building
90.1-2007 Res 3A Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:3A
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 4B Roof Attic and Other
90.1-2007 Res 4B Roof Attic and Other
Effective R-value6.297
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-38
Construction TypeAttic and Other
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 4B Roof IEAD
90.1-2007 Res 4B Roof IEAD
Effective R-value3.475
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-20 ci
Construction TypeInsulation Entirely Above Deck
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component
90.1-2007 Res 4B Roof Metal Building
90.1-2007 Res 4B Roof Metal Building
Effective R-value2.522
Film Coefficientsfalse
Insulation Minimum R-value (ft^2 F h/Btu)R-19
Construction TypeMetal Building
ConstructionRoof
Climate ZoneASHRAE 2004:4B
OpenStudio TypeOS:Construction
StandardASHRAE 90.1-2007
Standard TypeResidential
11/01/2013 Download Component