AedgK12Swh

Measure Details

NameAedg_k_12_swh
Display NameAedgk12swh
uuid081b3ccb-fc4a-48f7-ad50-87c90c20f9f9
TypeMeasure
Language Ruby
Tags Service Water Heating.Water Heating
DescriptionMeasure replaces existing swh equipment (if any) with the swh equipment recommendations of the 50% K-12 AEDG.
Modeler's DescriptionMeasure is applied to restroom and kitchen space types for both primary and secondary schools, and to gyms for secondary schools. All existing swh systems are deleted. The largest kitchen and gym spaces are selected as representative spaces, to which the corresponding AEDG recommended swh loads are applied. For restrooms, the total SWH load is divided evenly among the restroom spaces in the model. Loads are applied on a per student basis. The user can input number of students manually. Otherwise, the measure will calculate the number of students from the classroom floor area. If there is no classroom floor area, the user wil be required to specify a number of students.
Measure TypeModelMeasure
Uses SketchUp APIfalse
OpenStudio Version2.0.0
Minimum Compatible OpenStudio Version2.8.0
README FileREADME.md
GitHub RepoNREL/openstudio-aedg-gem

Versions

Version ID GitHub Release Tag OpenStudio Version Min Compatible Version Max Compatible Version Download Link
6412dd99-7219-42d6-a5fa-07ba31638203 v0.8.0 2.0.0 2.8.0 Download v0.8.0
6412dd99-7219-42d6-a5fa-07ba31638203 v0.6.0 2.0.0 2.8.0 Download v0.6.0
6412dd99-7219-42d6-a5fa-07ba31638203 v0.5.0 2.0.0 2.8.0 Download v0.5.0
9fa76450-2031-49d4-930a-af26b5f78569 v0.1 2.0.0 2.0.0 Download v0.1