Replace Exterior Window Constructions with a Different Construction from the Model.

Measure Details

NameReplace_exterior_window_construction
Display NameReplace Exterior Window Constructions With A Different Construction From The Model.
uuid95116deb-0716-4cdc-af27-09c463befc7c
TypeMeasure
Language Ruby
Tags Envelope.Fenestration
DescriptionReplace existing windows with different windows to change thermal or lighting performance. Window technology has improved drastically over the years, and double or triple-pane high performance windows currently on the market can cut down on envelope loads greatly. Window frames with thermal breaks reduce the considerable energy that can transfer through thermally unbroken frames. High performance windows typically also come with low-emissivity (low?e) glass to keep radiant heat on the same side of the glass from where the heat originated. This means that during the cooling months a low-e glass would tend to keep radiant heat from the sun on the outside of the window, which would keep the inside of a building cooler. Conversely, during heating months low-e glass helps keep radiant heat from inside the building on the inside, which would keep the inside of a building warmer. Life cycle cost values may be added for the new window applied by the measure.
Modeler's DescriptionReplace fixed and/or operable exterior window constructions with another construction in the model. Skylights (windows in roofs vs. walls) will not be altered. Windows in surfaces with "Adiabatic" boundary conditions are not specifically assumed to be interior or exterior. As a result constructions used on windows in "Adiabatic" surfaces will not be altered. Material & installation, demolition, and O&M costs can be added to the applied window construction. Optionally any prior costs associated with construction can be removed. For costs added as part of a design alternatives "Years Until Costs Start? is typically "0?. For a new construction scenario "Demolition Costs Occur During Initial Construction?? is "false?. For retrofit scenario "Demolition Costs Occur During Initial Construction?? is "true?. O&M cost and frequency can be whatever is appropriate for the component.
Measure TypeModelMeasure
Measure FunctionMeasure
Requires EnergyPlus Resultsfalse
Uses SketchUp APIfalse
OpenStudio Version2.0.0
Minimum Compatible OpenStudio Version2.0.0
README FileREADME.md
GitHub RepoNREL/openstudio-common-measures-gem

Versions

Version ID GitHub Release Tag OpenStudio Version Min Compatible Version Max Compatible Version Download Link
8179147f-e9e7-4580-b10e-51a102d4c454 v0.11.0 2.0.0 2.0.0 Download v0.11.0
91ef97e1-ec9e-4f25-bc3a-4a0374375bbf v0.10.0 2.0.0 2.0.0 Download v0.10.0
bb79400e-c308-442f-bd56-52e1238b4cd0 v0.9.0 2.0.0 2.0.0 Download v0.9.0
bb79400e-c308-442f-bd56-52e1238b4cd0 v0.8.0 2.0.0 2.0.0 Download v0.8.0
537e5262-4238-40d5-98d3-5af3d7b8ee4c v0.6.1 2.0.0 2.0.0 Download v0.6.1
537e5262-4238-40d5-98d3-5af3d7b8ee4c v0.6.0 2.0.0 2.0.0 Download v0.6.0
537e5262-4238-40d5-98d3-5af3d7b8ee4c v0.5.0 2.0.0 2.0.0 Download v0.5.0
1f92ce50-a8a1-46cf-8eb0-914f3abcf2cc v0.1 2.0.0 2.0.0 Download v0.1