Search Results
Results 1 to 25 out of 47
Name | Type | Description | Download |
---|---|---|---|
SetNISTInfiltrationCorrelations | Ruby measure | This measure incorporates infiltration that varies with weather and HVAC operation, and takes into account building geometry (height, above-ground exterior surface area, and volume). It is based on work published by Ng et al. (2018) |
download SetNISTInfiltrationCorrelations |
SetEnergyPlusInfiltrationFlowRatePerFloorArea | Ruby measure | Set the flow rate per floor area value for all infiltration objects in the model. Input values are in SI units. Repo: NREL/openstudio-common-measures-gem |
download SetEnergyPlusInfiltrationFlowRatePerFloorArea |
Set Space Infiltration by Exterior Surface Area | Ruby measure | Replace all Space Infiltration objects with a new one that has a prescribed flow rate per exterior surface area. There are many strategies that can be used to reduce infiltration.
Seal Windows ? Seal all windows and doors with weather strip and fill any air gaps with insulation and... Repo: NREL/openstudio-common-measures-gem |
download Set Space Infiltration by Exterior Surface Area |
SetSpaceInfiltrationPerExteriorArea | Ruby measure | Set Space Infiltration Design Flow Rate per exterior area for the entire building. Repo: NREL/openstudio-common-measures-gem |
download SetSpaceInfiltrationPerExteriorArea |
ReduceSpaceInfiltrationByPercentage | Ruby measure | This measure will reduce space infiltration rates by the requested percentage. A cost per square foot of building area can be added to the model. Repo: NREL/openstudio-ee-gem |
download ReduceSpaceInfiltrationByPercentage |
AedgK12EnvelopeAndEntryInfiltration | Ruby measure | This measure addresses two sources of air infiltration. The first is infiltration through the building envelope. The second is infiltration due to occupants entering and leaving the building. The AEDG provides recommendations and tips on how to limit infiltration in both cases. For occupant... Repo: NREL/openstudio-aedg-gem |
download AedgK12EnvelopeAndEntryInfiltration |
AedgSmallToMediumOfficeEnvelopeAndEntryInfiltration | Ruby measure | This measure addresses two sources of air infiltration. The first is infiltration through the building envelope. The second is infiltration due to occupants entering and leaving the building. The AEDG provides recommendations and tips on how to limit infiltration in both cases. For occupant... Repo: NREL/openstudio-aedg-gem |
download AedgSmallToMediumOfficeEnvelopeAndEntryInfiltration |
ZEDG K12 Envelope Infiltration | Ruby measure | This measure addresses total building infiltration values. Repo: NREL/openstudio-aedg-gem |
download ZEDG K12 Envelope Infiltration |