Add Central Ice Storage measure This measure adds an ice storage tank to a chilled water loop for the purpose of thermal energy storage. download Add Central Ice Storage
Add Packaged Ice Storage measure This measure removes the cooling coils in the model and replaces them with packaged air conditioning units with integrated ice storage. download Add Packaged Ice Storage
Cooling Coils Water Multiplier measure This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier. download Cooling Coils Water Multiplier
Cooling Coils Water PercentChange measure This is a general purpose measure to calibrate Water Cooling Coils with a PercentChange. download Cooling Coils Water PercentChange
Cooling Coils DX Single Speed Multiplier measure This is a general purpose measure to calibrate DX Cooling Coils with a Multiplier. download Cooling Coils DX Single Speed Multiplier
Cooling Coils DX Two Speed Percent Change measure This is a general purpose measure to calibrate DX Cooling Coils with a Percent Change. download Cooling Coils DX Two Speed Percent Change
Cooling Coils DX Two Speed Multiplier measure This is a general purpose measure to calibrate DX Cooling Coils with a Multiplier. download Cooling Coils DX Two Speed Multiplier
Cooling Coils DX Single Speed Percent Change measure This is a general purpose measure to calibrate DX Cooling Coils with a Percent Change. download Cooling Coils DX Single Speed Percent Change
Replace Water Heater Mixed with Thermal Storage Chilled Water measure This measure is a quick fix for GUI issue that prevents putting thermal storage on two plant loops. download Replace Water Heater Mixed with Thermal Storage Chilled Water
Set COP for Single Speed DX Cooling Units measure This measure will find single speed DX cooling units in the model and will alter the Rated COP to a specified value. It can be run on a single or... download Set COP for Single Speed DX Cooling Units
ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects measure Set various values for existing CoilCoolingDXSingleSpeed objects. Input values are in SI units. download ModifyEnergyPlusCoilCoolingDXSingleSpeedObjects
Set COP for Two Speed DX Cooling Units measure This measure will find two speed DX cooling units in the model and will alter the Rated HighSpeed COP to a specified value. It can be run on a... download Set COP for Two Speed DX Cooling Units
Add Waterside Economizer measure This measure adds a waterside economizer to provide free cooling to a user-selected chilled water loop from a user-selected condenser water loop... download Add Waterside Economizer