Search Results
Results 1 to 25 out of 249
Name | Type | Description | Download |
---|---|---|---|
Roof Thermal Properties Multiplier | Ruby measure | Change Roof by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Multiplier Repo: NREL/openstudio-calibration-gem |
download Roof Thermal Properties Multiplier |
Change R-value of Insulation Layer for Construction By a Specified Percentage | Ruby measure | Change R-value of Insulation Layer for Construction By a Specified Percentage Repo: NREL/openstudio-calibration-gem |
download Change R-value of Insulation Layer for Construction By a Specified Percentage |
Roof Thermal Properties Percent Change | Ruby measure | Change Roof by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Percent Change Repo: NREL/openstudio-calibration-gem |
download Roof Thermal Properties Percent Change |
Change Parameters Of Material (Layer 0 of Construction) | Ruby measure | This measure changes properties of Layer 0 for a specific construction. Repo: NREL/openstudio-calibration-gem |
download Change Parameters Of Material (Layer 0 of Construction) |
Exterior Wall Thermal Properties Multiplier | Ruby measure | Change exterior walls by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Multiplier Repo: NREL/openstudio-calibration-gem |
download Exterior Wall Thermal Properties Multiplier |
Exterior Wall Thermal Percent Change | Ruby measure | Change exterior walls by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Percent Change Repo: NREL/openstudio-calibration-gem |
download Exterior Wall Thermal Percent Change |
Change R-value of Insulation Layer for Construction By a Multiplier | Ruby measure | Change R-value of Insulation Layer for Construction By a Multiplier Repo: NREL/openstudio-calibration-gem |
download Change R-value of Insulation Layer for Construction By a Multiplier |
Thermal Bridging and Derating - TBD | Ruby measure | Derates opaque constructions from major thermal bridges. Repo: rd2/tbd |
download Thermal Bridging and Derating - TBD |
RemoveHardAssignedConstructions | Ruby measure | This will remove all construction assignments from made directly to surfaces or sub-surfaces. This may useful if you started with an Imported IDF file and now want to use construction sets. Repo: NREL/openstudio-model-articulation-gem |
download RemoveHardAssignedConstructions |
SetInteriorWallsAndFloorsToAdiabatic | Ruby measure | Set interior walls to Adiabatic and assign a hard construction. Repo: NREL/openstudio-model-articulation-gem |
download SetInteriorWallsAndFloorsToAdiabatic |
Add EMPD Material Properties | Ruby measure | Adds the properties for the effective moisture penetration depth (EMPD) Heat Balance Model with inputs for penetration depths. Repo: NREL/openstudio-model-articulation-gem |
download Add EMPD Material Properties |
SetExtWallToGroundBoundaryConditionByStory | Ruby measure | Use this to setup one of your building stories as a basement. Repo: NREL/openstudio-model-articulation-gem |
download SetExtWallToGroundBoundaryConditionByStory |
SetInteriorWallsToSelectedConstruction | Ruby measure | Replace all interior walls with the specified construction. Repo: NREL/openstudio-model-articulation-gem |
download SetInteriorWallsToSelectedConstruction |
AssignConstructionSetToBuilding | Ruby measure | This will assign an existing construction set to the building object. This will impact surfaces that don't have construction sets already assigned at story, space type, space, or surfaces with hard assigned constructions. Repo: NREL/openstudio-model-articulation-gem |
download AssignConstructionSetToBuilding |
RenameSpaceSurfacesBasedonParentSpaceandOrientation | Ruby measure | This will rename surfaces so so that they will look like "Surface MySpace1 wall 230-01" where "MySpace1" is the name of my space "wall" is the surface type and 230 is the orientation of the surface and 01 is the first surface of that orientation. SubSurfaces will start with SubSurface instead of... Repo: NREL/openstudio-model-articulation-gem |
download RenameSpaceSurfacesBasedonParentSpaceandOrientation |
Set Exterior Walls and Floors to Adiabatic | Ruby measure | Set exterior or ground walls, floors, and roofs to Adiabatic and assign a hard construction. Can specify through bool arguments exterior orientation for walls, as well as floors and roofs. Repo: NREL/openstudio-common-measures-gem |
download Set Exterior Walls and Floors to Adiabatic |
Increase R-value of Insulation for Exterior Walls to a Specific Value | Ruby measure | Set the R-Value of exterior wall insulation to a specified value. Higher R-Values provide better insulation, lowering heat loss and heat gain through the exterior walls. Costs for a construction can be adjusted Repo: NREL/openstudio-ee-gem |
download Increase R-value of Insulation for Exterior Walls to a Specific Value |
Increase R-value of Insulation for Exterior Walls By a Specified Percentage | Ruby measure | Increase the R value of the insulation layer in wall constructinons by a percentage. Repo: NREL/openstudio-ee-gem |
download Increase R-value of Insulation for Exterior Walls By a Specified Percentage |
Increase R-value of Insulation for Roofs by a Specified Percentage. | Ruby measure | Increase the R value of the insulation layer in roof constructinons by a percentage. Repo: NREL/openstudio-ee-gem |
download Increase R-value of Insulation for Roofs by a Specified Percentage. |
Increase R-value of Insulation for Roofs to a Specific Value | Ruby measure | Set the R-Value of roof insulation to a specified value. Higher R-Values provide better insulation, lowering heat loss and heat gain through the roof. Repo: NREL/openstudio-ee-gem |
download Increase R-value of Insulation for Roofs to a Specific Value |
IdfToOsm | Ruby measure | Translate IDF to OSM Repo: automaticmagic/automaticmagic-measures |
download IdfToOsm |
AedgK12ExteriorWallConstruction | Ruby measure | This measure will modify existing exterior wall insulation levels based on construction type and climate zone. The exterior wall construction type and climate zone should be set in the model prior to using this measure. For mass and metal walls if an existing insulation layer can be found it... Repo: NREL/openstudio-aedg-gem |
download AedgK12ExteriorWallConstruction |
AedgSmallToMediumOfficeSlabAndBasement | Ruby measure | This measure applies Small to Medium Office AEDG 50% recommendations for slab and below grade walls. It can also be used to model and simulate ASHRAE 90.1 2004 slab and below grade wall insulation levels. Note that for many climate zones (1-3), if your model doesn't have below grade walls or... Repo: NREL/openstudio-aedg-gem |
download AedgSmallToMediumOfficeSlabAndBasement |
ZEDG K12 RoofConstruction | Ruby measure | ZEDG version, only setup for IEAD roof. This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof type and climate zone should be set in the model prior to using this measure. If your model uses an attic, all... Repo: NREL/openstudio-aedg-gem |
download ZEDG K12 RoofConstruction |
AedgK12RoofConstruction | Ruby measure | This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof type and climate zone should be set in the model prior to using this measure. If your model uses an attic, all attic surfaces should have an "Attic'... Repo: NREL/openstudio-aedg-gem |
download AedgK12RoofConstruction |