Name |
Type |
Description |
Download |
Thermal Bridging and Derating - TBD |
measure |
Derates opaque constructions from major thermal bridges. |
|
Increase R-value of Insulation for Exterior Walls to a Specific Value |
measure |
Set the R-Value of exterior wall insulation to a specified value. Higher R-Values provide better insulation, lowering heat loss and heat gain... |
|
Increase R-value of Insulation for Exterior Walls By a Specified Percentage |
measure |
Increase the R value of the insulation layer in wall constructinons by a percentage. |
|
Increase R-value of Insulation for Roofs by a Specified Percentage. |
measure |
Increase the R value of the insulation layer in roof constructinons by a percentage. |
|
Increase R-value of Insulation for Roofs to a Specific Value |
measure |
Set the R-Value of roof insulation to a specified value. Higher R-Values provide better insulation, lowering heat loss and heat gain through the roof. |
|
RemoveHardAssignedConstructions |
measure |
This will remove all construction assignments from made directly to surfaces or sub-surfaces. This may useful if you started with an Imported IDF... |
|
SetInteriorWallsAndFloorsToAdiabatic |
measure |
Set interior walls to Adiabatic and assign a hard construction. |
|
SetExtWallToGroundBoundaryConditionByStory |
measure |
Use this to setup one of your building stories as a basement. |
|
SetInteriorWallsToSelectedConstruction |
measure |
Replace all interior walls with the specified construction. |
|
AssignConstructionSetToBuilding |
measure |
This will assign an existing construction set to the building object. This will impact surfaces that don't have construction sets already assigned... |
|
RenameSpaceSurfacesBasedonParentSpaceandOrientation |
measure |
This will rename surfaces so so that they will look like "Surface MySpace1 wall 230-01" where "MySpace1" is the name of my space "wall" is the... |
|
Exterior Wall Thermal Properties Multiplier |
measure |
Change exterior walls by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Multiplier |
|
Exterior Wall Thermal Percent Change |
measure |
Change exterior walls by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Percent Change |
|
Roof Thermal Properties Multiplier |
measure |
Change Roof by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Multiplier |
|
Roof Thermal Properties Percent Change |
measure |
Change Roof by altering the thermal resistance, density, and solar absorptance of the wall constructions by a Percent Change |
|
IdfToOsm |
measure |
Translate IDF to OSM |
|
Add EMPD Material Properties |
measure |
Adds the properties for the effective moisture penetration depth (EMPD) Heat Balance Model with inputs for penetration depths. |
|
AedgK12ExteriorWallConstruction |
measure |
This measure will modify existing exterior wall insulation levels based on construction type and climate zone. The exterior wall construction type... |
|
AedgSmallToMediumOfficeSlabAndBasement |
measure |
This measure applies Small to Medium Office AEDG 50% recommendations for slab and below grade walls. It can also be used to model and simulate... |
|
ZEDG K12 RoofConstruction |
measure |
ZEDG version, only setup for IEAD roof. This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on... |
|
AedgK12RoofConstruction |
measure |
This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof... |
|
AedgSmallToMediumOfficeExteriorDoorConstruction |
measure |
This measure is intended for use on opaque doors; if doors are glass they should be treated as windows. OpenStudio does have a unique object for... |
|
AedgSmallToMediumOfficeExteriorFloorConstruction |
measure |
This measure will modify existing exterior floor (air exposed) insulation levels based on construction type and climate zone. The exterior floor... |
|
AedgSmallToMediumOfficeRoofConstruction |
measure |
This measure will modify existing roof insulation levels and Solar Reflective Index (SRI) values based on roof type and climate zone. The roof... |
|
AedgK12ExteriorDoorConstruction |
measure |
This measure is intended for use on opaque doors; if doors are glass they should be treated as windows. OpenStudio does have a unique object for... |
|