Search Results

Results 1 to 25 out of 397

Name Type Description Download
Cooling Coils Water Multiplier Ruby measure This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Cooling Coils Water Multiplier
Cooling Coils Water PercentChange Ruby measure This is a general purpose measure to calibrate Water Cooling Coils with a PercentChange.
Repo: NREL/openstudio-calibration-gem
download Cooling Coils Water PercentChange
Hard Size HVAC Ruby measure Run a simulation to autosize HVAC equipment and then apply these autosized values back to the model.
Repo: NREL/openstudio-calibration-gem
download Hard Size HVAC
Cooling Coils DX Single Speed Multiplier Ruby measure This is a general purpose measure to calibrate DX Cooling Coils with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Cooling Coils DX Single Speed Multiplier
Cooling Coils DX Two Speed Percent Change Ruby measure This is a general purpose measure to calibrate DX Cooling Coils with a Percent Change.
Repo: NREL/openstudio-calibration-gem
download Cooling Coils DX Two Speed Percent Change
Cooling Coils DX Two Speed Multiplier Ruby measure This is a general purpose measure to calibrate DX Cooling Coils with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Cooling Coils DX Two Speed Multiplier
Heating Coils Electric Multiplier Ruby measure This is a general purpose measure to calibrate Electric Heating Coils with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Heating Coils Electric Multiplier
Heating Coils Gas Percent Change Ruby measure This is a general purpose measure to calibrate Gas Heating Coils with a Percent Change.
Repo: NREL/openstudio-calibration-gem
download Heating Coils Gas Percent Change
Heating Coils Water Multiplier Ruby measure This is a general purpose measure to calibrate Water Heating Coils with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Heating Coils Water Multiplier
Heating Coils Water Percent Change Ruby measure This is a general purpose measure to calibrate Water Heating Coils with a Percent Change.
Repo: NREL/openstudio-calibration-gem
download Heating Coils Water Percent Change
Fans Percent Change Ruby measure This is a general purpose measure to calibrate Fans with a Percent Change.
Repo: NREL/openstudio-calibration-gem
download Fans Percent Change
Cooling Coils DX Single Speed Percent Change Ruby measure This is a general purpose measure to calibrate DX Cooling Coils with a Percent Change.
Repo: NREL/openstudio-calibration-gem
download Cooling Coils DX Single Speed Percent Change
Heating Coils Electric Percent Change Ruby measure This is a general purpose measure to calibrate Electric Heating Coils with a Percent Change.
Repo: NREL/openstudio-calibration-gem
download Heating Coils Electric Percent Change
Heating Coils Gas Multiplier Ruby measure This is a general purpose measure to calibrate Gas Heating Coils with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Heating Coils Gas Multiplier
Fans Multiplier Ruby measure This is a general purpose measure to calibrate Fans with a Multiplier.
Repo: NREL/openstudio-calibration-gem
download Fans Multiplier
Replace Thermostat Schedules Ruby measure Replace zone thermostat schedules with other schedules in the same file. If a zone does not have a thermostat this measure will not add one.
Repo: NREL/openstudio-common-measures-gem
download Replace Thermostat Schedules
Set COP for Single Speed DX Cooling Units Ruby measure This measure will find single speed DX cooling units in the model and will alter the Rated COP to a specified value. It can be run on a single or all air loops in the model.
Repo: NREL/openstudio-common-measures-gem
download Set COP for Single Speed DX Cooling Units
EnableIdealAirLoadsForAllZones Ruby measure This will enable Ideal Air Loads for all thermal zones in the model. This will result in disconnecting any pre-existing HVAC systems from the zones.
Repo: NREL/openstudio-common-measures-gem
download EnableIdealAirLoadsForAllZones
Set Gas Burner Efficiency Ruby measure This measure will find Coil Heating Gas units in the model and will alter the burner efficiency to a specified value. It can be run on a single or all air loops in the model.
Repo: NREL/openstudio-common-measures-gem
download Set Gas Burner Efficiency
ModifyEnergyPlusFanVariableVolumeObjects Ruby measure Set the Maximum Flow Rate and and Pressure Rise values for all Fan:VariableVolume objects in the model. Input values are in SI units.
Repo: NREL/openstudio-common-measures-gem
download ModifyEnergyPlusFanVariableVolumeObjects
Add Zone Mixing Object Ruby measure This adds a zone mixing object with a few inputs exposed, including source zone. You can add multiple copies of this to the workflow as needed.
Repo: NREL/openstudio-common-measures-gem
download Add Zone Mixing Object
Adjust Thermostat Setpoints by Degrees Ruby measure This measure adjusts heating and cooling setpoints by a user specified number of degrees. This is applied throughout the entire building.
Repo: NREL/openstudio-common-measures-gem
download Adjust Thermostat Setpoints by Degrees
Set Thermostat Schedules Ruby measure Sets zone thermostat schedules to schedules in the same file. If a zone does not have a thermostat this measure will add one
Repo: NREL/openstudio-common-measures-gem
download Set Thermostat Schedules
Air Wall Zone Mixing Ruby measure This measure replaces conductive heat transfer with zone mixing wherever air walls are used on matched surfaces or sub-surfaces for walls. A user argument is exposed for a coefficient that represents a target air changes per hour (ACH) for a room where the zone volume/the air wall surface area...
Repo: NREL/openstudio-common-measures-gem
download Air Wall Zone Mixing
AdjustSystemEfficiencies Ruby measure Updates heating and cooling efficiencies of all equipment in a model by a multiplier.
Repo: NREL/openstudio-common-measures-gem
download AdjustSystemEfficiencies